Units for the output axis
The position units for the output axis are shown below based on the setting "[Pr.1] Unit setting".
Setting value of "[Pr.1] Unit setting"
0: mm
1: inch
2: degree
3: pulse
Cam axis cycle units are shown below based on the setting "[Pr.438] Cam axis cycle unit setting".
Setting value of "[Pr.438] Cam axis cycle unit
setting"
Unit setting selection
Control
unit
0: Use units of main input
axis
1: Use units of this setting
0: mm
1: inch
2: degree
3: pulse
Output axis position unit
-4
 10
mm
-1
(  10
m)
-5
 10
inch
-5
 10
degree
pulse
Cam axis cycle unit
Number of
decimal
places
Servo input axis position unit (Page 29 Servo input axis position units)
Synchronous encoder axis position unit (Page 36 Synchronous encoder axis position
units)
0
mm
-9
9
 10
mm
0
inch
-9
9
 10
inch
0
degree
-9
9
 10
degree
0
pulse
-9
9
 10
pulse
Range
-214748.3648 to 214748.3647 [mm]
(-214748364.8 to 214748364.7 [m])
-21474.83648 to 21474.83647 [inch]
-21474.83648 to 21474.83647 [degree]
-2147483648 to 2147483647 [pulse]
Range
-2147483648 to 2147483647 [mm]
-2.147483648 to 2.147483647 [mm]
-2147483648 to 2147483647 [inch]
-2.147483648 to 2.147483647 [inch]
-2147483648 to 2147483647 [degree]
-2.147483648 to 2.147483647 [degree]
-2147483648 to 2147483647 [pulse]
-2.147483648 to 2.147483647 [pulse]
4 ADVANCED SYNCHRONOUS CONTROL