Huawei AP8082DN Hardware Installation And Maintenance Manual page 64

Table of Contents

Advertisement

AP8082DN and AP8182DN
Hardware Installation and Maintenance Guide
Figure 6-11 Components of the DC round waterproof connector
1. Enclosure
Procedure
Step 1 Determine the diameter of the cable to be installed. If the diameter is larger than 14 mm,
replace the clamping jaw, as shown in
clamping jaw boss to the groove inside the socket and ensure that the clamping jaw is
completely installed in the socket, as shown in
Figure 6-12 Replacing clamping jaws
1. Clamping jaw 1
Issue 03 (2019-04-01)
2. Socket
NOTE
l
Power cables supported by clamping jaw 1: 2 x 12 AWG, 2 x 4 mm
l
Power cables supported by clamping jaw 2: 2 x 8 AWG and 2 x 10 mm
Copyright © Huawei Technologies Co., Ltd.
3-1. Clamping jaw 1
Figure
6-12. During the replacement, connect the
Figure
2. Clamping jaw 2
3-2. Clamping jaw 2
6-13.
2
, and 2 x 6 mm
2
6 Appendix
4. Nut
2
57