Assembling A Straight Male Coaxial N Connector And An Rg8U Feeder - Huawei AP8082DN Hardware Installation And Maintenance Manual

Table of Contents

Advertisement

AP8082DN and AP8182DN
Hardware Installation and Maintenance Guide
Figure 6-95 Installing the connector
----End
Follow-up Procedure
After a type N connector is made, perform the short-circuit test using a multimeter as follows:
1.
2.
3.
4.

6.1.4.2 Assembling a Straight Male Coaxial N Connector and an RG8U Feeder

Context
Figure 6-96
Issue 03 (2019-04-01)
Use the multimeter to test the conductivity between signal pins of the type N connector
and signal wires of the radio cable. If they are not conductive, re-assemble the radio
cable.
Use the multimeter to test the conductivity between the metal shell of the type N
connector and base wires of the radio cable. If they are not conductive, re-assemble the
radio cable.
Test the conductivity between the metal shell signal pins of the type N connector. If they
are not conductive, re-assemble the radio cable.
Test the conductivity between signal wires of the radio cable and the metal shielding
ground cable. If they are conductive, re-assemble the radio cable.
shows the coaxial N connector and RG8U feeder.
Copyright © Huawei Technologies Co., Ltd.
6 Appendix
103