Removing the Lithium-Ion Battery (continued)
Electrical System: Service and Repairs
g339409
1.
Negative (-) terminal
2.
Lithium-ion battery
3.
Positive (+) terminal
1. Park the machine on a level surface and make sure that the clutch bail in the
NEUTRAL position. Turn the key switch to the OFF position and remove
the key from the key switch.
2. Disconnect the battery pack; refer to
(page
5–3).
3. Remove the four bolts that secures the battery cover to the battery mount.
Remove the battery cover from the machine.
4. Label and disconnect the negative (-) battery cable, positive (+) battery cable,
and battery interface harness from the lithium-ion battery; refer to
g339388
1.
Bolt (4 each)
2.
Washer (4 each)
3.
Lithium-ion battery
5. Remove the four nuts (item 5 in
secures the battery to the battery mount.
Figure 74
4.
Washer
5.
Lock washer
6.
Nut
Connecting the Lithium Battery Pack
Figure 75
4.
Battery mount
5.
Nut (4 each)
Figure
75), bolts (1) and washers (2) that