Panasonic DVC PRO Studio AJ-D950P Service Manual page 5

Vtr/analog video interface kit
Table of Contents

Advertisement

1. Turns power OFF and set the DIP SW 501-1 to ON position on the
SYSCON (F2) P.C.B.
2. Turns power ON and press DIAG button and then press SEARCH
button. Confirm the HOUR METER information is displayed on the
monitor as above figure.
3. Set the cursor to mark "r" position by rotating the jog JOG DIAL
then press the RESET button.
4. The message is displayed as below. (The following message is a
example when "DRUM RUN r ".)
5. Set the DIP SW 501-1 to OFF position on the SYSCON (F2) P.C.B.
Note:
Accumulated Time can not be reset.
4.2. How to confirm the Soft Version
1. Turns power ON.
2. Press the EJECT button.
3. When press the PLAY and STOP button simultaneously, the soft
version is displayed on the front panel.
4. By repeating step 3, the display of version is changed as follows.
5. Maintenance & Mechanical Adjustment
5.1. Maintenance Parts Chart