4. Then input the all data (37 items for NTSC) and check sum. IF the
data is incorrect registration is not completed so check and input
again.
After data registration select <1> SELECT.
5.6.33. RP Head Sensitivity Adjustment (25M Mode)
Specification
Mode
Test Point
Adjustment
Tape
Before this Adjustment adjust RFEQ (H3/H4) ENV Level Adjustment(L/R).
Set the LISTA software in 25M Mode. Select AJ-D950 in the PC menu and displays the main
menu. 25M and 50m mode can be changed by " 0" key.
1. Set the VTR in Service Mode to open the service menu and select
the item of " A09 RP GAIN DP" in the " SERVO ADJUST" menu.
2. Playback a LISTA alignment tape (VFM3581KM).
3. Select the LISTA (6) ATF Error Signal Monitor and " 1.2% Speed..."
and type Enter to start the software.
4. When the picture is appeared as shown in figure adjust ATF Gain
so that the " Sens. Value:" is in the Specification. To return the
main menu press ESC key.
5.6.34. RP Head Sensitivity Detection (25M Mode)
Specification
Mode
Test Point
Adjustment
Tape
Sensitivity 150+/-15 (mV/um)
Playback
(1) ATF:TP732 (2) HSW:TP722(RP HSW) (not TP723(PB HSW)
(3) GND:TG510
SERVO Adjustment Menu:"A09 RP GAIN P"
VFM3581KM or VFM3581KL
Sensitivity 150+/-15 (mV/um)
Playback
(1) ATF:TP732 (2) HSW:TP722(RP HSW) (not TP723(PB HSW)
(3) GND:TG510
SERVO Adjustment Menu: " A09 RP GAIN DP"
VFM3581KM or VFM3581KL
43