6.10.4. COMPONENT Pr LEVEL ADJ.
BOARD
SPEC.
TEST POINT
ADJ.
INPUT
MODE
TAPE
M.EQ
1. Adjust VR3004 so that the Pr level is 700mV±7mV.
6.10.5. COMPONENT Y CLAMP LEVEL ADJ.
BOARD
SPEC.
TEST POINT
ADJ.
INPUT
MODE
TAPE
M.EQ
1. Adjust VR3007 so that the Y clamped pedestal level is at scope
GND level.
F6 SUB
700mV±7mV
Pr_OUT
VR3004
SDI IN 100% CB 0% SETUP
EE
WFM
F6 SUB
0V±50mV
Y-OUT
VR3007
SDI IN 100% CB 0% SETUP
EE
OSCILLOSCOPE
166