1-1-15.
COMPOSITE PB LEVEL ADJ.
BOARD
F3 V IN
SPEC.
V 486mV ± 7mV
TEST POINT
Component PB out
ADJ.
VR505
Composite Color Bar
INPUT
75%
MODE
ASSEMBLE
TAPE
M.EQ
WFM
Adjust VR505 so that the Pb level is 486mV ± 7mV.
1.
Setup 7.5%
1-1-16.
COMPOSITE PR LEVEL ADJ.
BOARD
F3 V IN
SPEC.
V 486mV ± 7mV
TEST POINT
Component PR out
ADJ.
VR511
Composite Color Bar
INPUT
75%
MODE
ASSEMBLE
TAPE
M.EQ
WFM
Adjust VR511 so that the Pr level is 486mV ± 7mV.
1.