3-7-16. S5 Post Base Unit Replacement
(Removal of S5 Post Base Unit)
1.
Remove the top panel.
2.
Remove the front loading unit.
3.
Remove the screw (A) and remove the S5 Post
Base Unit.
(Installation of S5 Base Unit)
1.
Install the new S5 Post Base Unit as reverse order
of its removal.
(Note) Install the S5 Post by the position fix as
shown in the figure.
2.
After installation, Post Pre-adjustment and Linearity
adjustment are necessary.
Screw (A)
Removal of S5 Post Base Unit
3-7-17. Replacement of Tension Arm Unit
(Removal of Tension Arm Unit)
1.
Remove the top panel.
2.
Remove the front loading unit.
3.
Remove the cut washer (A) and remove the tension
regulator spring from its hook then remove the
tension arm unit.
S5 Post Base
Unit
(Installation of Tension Arm Unit)
1.
Install the new Tension Arm Unit as reverse order of
its removal.
2.
After installation adjust tension arm adjustment
following the tension arm adjustment flow chart.
Cut Washer (A)
Removal of Tension Arm Unit
Tension Arm Adjustment Flow Chart
Start
Tension Arm Offset Voltage Adjustment
Tension Arm Neutral Position Adjustment
Tension Arm PLAY Voltage Adjustment
Tension Arm REV Voltage Confirm
Tension Arm Tension Regulator Spring Adj.
REV Tension Confirm
Screw Grew
END
Tension Arm Unit
Tension Regulator Spring
NG
NG

Advertisement

Table of Contents
loading

Table of Contents