Launching The Web-Client To View Live Video - Honeywell HNVE1 Reference Manual

1-channel encoder equip series
Table of Contents

Advertisement

Installing the Honeywell IP Utility and Web-Client Software

Launching the Web-Client to View Live Video

36
Updating IP Network Settings Manually
Caution
When manually updating the network settings, it is important to enter
the correct IP network settings before applying them. Incorrect values
may cause a failure when connecting to the device. See
definitions of each setting.
1.
In the Discovery pane, select the device and click Connect
2.
To assign a static IP address to the device, from the System tab click to clear the
Obtain an IP Address automatically check box.
3.
Type in a Device Name, for example, FrontLobby01.
Note
The MAC address is a factory assigned address that is unique for each
device.
4.
Type in an IP Address of the device on the network.
Note
The address must be in the same address range. For example, if the PC is
192.188.1.xx, then the device should be set to a similar address, for example
192.168.1.xy.
5.
Type in the device Subnet Mask value. A value is required.
6.
Type in a default Gateway Address that connects the device to the static network. A
value is required.
7.
Click Apply.
The network settings are updated and a message displays in the status bar to confirm
the update.
Note
Up to six Web-Client users can log on to the Web-Client application at the
same time, in any combination of Administrator and Guest users that total six.
After you are logged on as an Administrator, there is no time out until you
click Logout.
Table 3-4