Encoder Installation

Mounting the HNVE1 Encoder

Choosing the Location

Mounting Considerations

Mounting in a Rack

24
Caution
Connect power either from a 12 VDC source or a CAT5 Ethernet
connector (PoE); never both at the same time.
Choose an installation location for the HNVE1 that:
Provides access to the correct and reliable power supply (see
and access to a video-in feed
Protects the encoder from dust, dirt, and liquids
Allows air to flow around the vents
Conforms with local regulatory guidelines
Avoid any installation environment where the HNVE1 is:
Exposed to strong vibrations or uneven surfaces
Exposed to direct sunlight or is near a heat source such as a radiator
Exposed to high humidity or where condensation forms easily
Near high-voltage cables such as a power cable
Exposed to dust and dirt
Exposed to extreme fluctuations in temperature
Do not block ventilation openings in the cover.
Install the HNVE1 in the rack as low as possible.
Securely mount the HNVE1 in a 19 in. EIA standard rack.
To mount the HNVE1 in the rack:
1.
Attach the mounting brackets (supplied) to the sides of the HNVE1 using the supplied
screws.
Electrical
on page 81)