E-Series Ethernet Utilization Window; E-Series Ethernet History Window; Maxbaserate For Sts Circuits; Ethernet History Statistics Per Time Interval - Cisco 15454-DS1-14= - 1.544Mbps Expansion Module Reference Manual

Reference manual
Table of Contents

Advertisement

Chapter 15
Performance Monitoring

15.6.1.2 E-Series Ethernet Utilization Window

The Utilization window shows the percentage of transmit (Tx) and receive (Rx) line bandwidth used by
the Ethernet ports during consecutive time segments. The Mode field displays the real-time mode status,
such as 100 Full, which is the mode setting configured on the E-Series port. However, if the E-Series
port is set to autonegotiate the mode (Auto), this field shows the result of the link negotiation between
the E-Series and the peer Ethernet device attached directly to the E-Series port.
The Utilization window provides an Interval drop-down list that enables you to set time intervals of
1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas:
Rx = (inOctets + inPkts * 20) * 8 / 100% interval * maxBaseRate
Tx = (outOctets + outPkts * 20) * 8 / 100% interval * maxBaseRate
The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction
for the Ethernet port (that is, 1 Gbps). The maxBaseRate for E-Series Ethernet cards is shown in
Table
Table 15-14
STS
STS-1
STS-3c
STS-6c
STS-12c
Note
Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity.
Note
The E-Series Ethernet card is a Layer 2 device or switch and supports Trunk Utilization statistics. The
Trunk Utilization statistics are similar to the Line Utilization statistics, but shows the percentage of
circuit bandwidth used rather than the percentage of line bandwidth used. The Trunk Utilization statistics
are accessed through the card view Maintenance tab.

15.6.1.3 E-Series Ethernet History Window

The Ethernet History window lists past Ethernet statistics for the previous time intervals. Depending on
the selected time interval, the History window displays the statistics for each port for the number of
previous time intervals as shown in
page
Table 15-15
Time Interval
1 minute
15 minutes
1 hour
1 day (24 hours)
78-18106-01
15-14.

maxBaseRate for STS Circuits

maxBaseRate
51840000
155000000
311000000
622000000
15-29.

Ethernet History Statistics per Time Interval

Number of Previous Intervals Displayed
60
32
24
7
15.6.1 E-Series Ethernet Card Performance Monitoring Parameters
Table
15-15. The parameters are defined in
Cisco ONS 15454 Reference Manual, R8.5
Table 15-13 on
15-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15454

Table of Contents