Related Documents For Pppox Calling Station Id; Configuration Tasks For Pppox Calling Station Id; Configuring The Calling-Station-Id Format; Verifying The Calling-Station-Id - Cisco 10000-2P2-2DC Software Configuration Manual

10000 series
Table of Contents

Advertisement

Chapter 16
Configuring RADIUS Features

Related Documents for PPPoX Calling Station ID

Configuration Tasks for PPPoX Calling Station ID

To configure the RADIUS Attribute 31: PPPoX Calling Station ID feature, perform the following
configuration tasks:

Configuring the Calling-Station-ID Format

To configure the Calling-Station-ID format, perform the following task in global configuration mode:
To verify the Extended NAS-Port-Type and NAS-Port-ID Attributes Support feature, enter the following
command in privileged EXEC mode:
Command
Router(config)# radius-server attribute 31 pppox
format

Verifying the Calling-Station-ID

To verify the Calling-Station-ID, perform the following task in EXEC mode use the debug radius
command in privileged EXEC mode. The debug radius command verifies that RADIUS attribute 31,
Calling-Station-ID, is in the ACCESS-REQUEST and ACCOUNTING-REQUEST.
shows sample output of the debug radius command.
Because debugging output is assigned high priority in the CPU process, it can render the system
Caution
unusable. For this reason, use debug commands only to troubleshoot specific problems or during
troubleshooting sessions with Cisco Systems technical support personnel. Moreover, it is best to use
OL-2226-23
RADIUS Logical Line ID feature guide
"Configuring Broadband Access: PPP and Routed Bridge Encapsulation" in the Cisco IOS
Wide-Area Networking Configuration Guide, Release 12.2
Cisco IOS Dial Technologies Configuration Guide, Release 12.2
Configuring the Calling-Station-ID Format
Verifying the Calling-Station-ID
Purpose
format—Specifies the type of Calling-Station-ID
nas-port—Enables the Nas-Port format of the
Calling-Station-ID attribute.
mac-addr—Enables the Mac-only format of the
Calling-Station-ID attribute.
You can enable one or both types of Calling-Station ID. If both
the MAC-only and Nas-Port types of Calling-Station-ID are
enabled, the system provides only the MAC address to the
RADIUS server for PPPoEoE sessions. See
page 16-52
for a summary of enabled Calling-Station-ID formats
by session type.
Cisco 10000 Series Router Software Configuration Guide
RADIUS Attribute 31: PPPoX Calling Station ID
Table 16-1 on
Example 16-2
16-53

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000510008

Table of Contents