• You can check the output status of the inverter by the lighting or blinking of the LED lamp.
• If it flashes, the protection function is activated and the power output is stopped. Be sure to stop
operation and remove the cause of the abnormality before restarting operation.
LED lamp status
1. Solid green light
2. Blinking green light
3. Blinking red light
4. Solid red light
5. No lights on
LED LAMP
Normal condition. Vibrator can be used.
The vibrator is overloaded. The vibrator can be used, but the vibration frequency has been
lowered to prevent failure due to overload. The vibrator will return to its normal state when
the overload condition is resolved.
In this state, the erroneous start prevention function is activated.
This function prevents the vibrator from starting up unexpectedly when the power is turned
on while the vibrator operation switch is in the ON position. Turning the operation switch to
OFF restores the vibrator to its normal state.
When an abnormality is detected, the output of the inverter is stopped.
When the red light turns on, please check the following.
• Check the remaining capacity of the battery.
• Is there any restraint or excessive load caused by rebar, etc.?
If no problem is found, turn the switch to OFF to return to the normal state (solid green light).
If the red light turns on repeatedly, a malfunction has likely occurred. Inspection and repair
are required.
Because there is a problem on the power supply, the vibrator has been stopped. The
battery may be dead, the battery may have been inserted incorrectly, or the battery may be
defective. Please check the power supply.