Parameter
Detection Area
Schedule
3. Click APPLY to save the settings.
Click COPY. In the Copy dialog box, select the additional channel(s)
that you want to copy the motion detection settings to, and then click
APPLY.

Figure 58 Copy dialog box

Setting the Motion Detection Area
1. On the live video screen, draw areas to arm.
You can configure four regions. Hold down and drag the left mouse
button to draw a motion detection area, the default area is full
screen.
Note: Drag on the screen to select the region that you want to detect. When
anyone of the four regions activates motion detect alarm, the channel
where this region belongs to will activate motion detect alarm.
The NVR is modified, the result can be synced to camera.
Honeywell 35 Series Network Video Recorder User Guide
Description
After a motion detection area is selected, double-click it to delete the
selected area.
Sensitivity: there are four level can be chosen,
Low/Medium/High/Highest, it is not consistent with IPC. The highest
the chosen is, the easier the alarms can be activated.
Define a period during which the motion detection is active.