When installing a HS-NCM (High-Speed Network Communications Module) on high-speed networks and workstations, adhere to the following to
avoid permanent damage:
Do not attempt to upgrade HS-NCM to software v30.x (or higher) on a network that utilizes v20 HS-NCMs using v20.4 (or lower) software. This
will result in permanent damage to all v20 HS-NCMs on the network
Attempting to individually upgrade any v20 HS-NCM with software V30.x (or higher) will result in permanent damage
When using v30 HS-NCM, VeriFire Tools v8.20 (or higher) is required for all HS-NCM software upgrades
When using an Ethernet cable (RJ45) to bridge a VDSL network with a BoradR-Reach network use VeriFire Tools version 10.80 (or higher)
When a HS-NCM-W-2, HS-NCM-WMF-2 or HS-NCM-WSF-2 is used in a network use VeriFire Tools version 10.80 (or higher)
1
Product Overview
NOTE:
References to V20 HS-NCM indicate hardware assembly HS-NCM-PCA.
References to V30.x and V31.x (or higher) HS-NCM indicate hardware assembly HS-NCM-PCB.
References to V31.x (or higher) indicate hardware assembly HS-NCM-W-2, HS-NCM-WMF-2, HS-NCM-WSF-2 (HS-NCM-PCC)
The High-Speed Network Communications Module (HS-NCM) provides a means for connecting specific Notifier fire alarm control products to High-
Speed NOTI•FIRE•NET™. There are six types of HS-NCMs available: HS-NCM-W/W-2 for connecting nodes with twisted-pair wire; HS-NCM-MF
and HS-NCM-SF are used for connecting nodes with fiber-optic cable; HS-NCM-WMF/WMF-2 and HS-NCM-WSF/WSF-2 are used for connecting
nodes with fiber-optic cables to nodes with twisted-pair wire; HS-NCM-MFSF for connecting nodes with multi-mode fiber cable to nodes with single-
mode fiber cable. The following equipment may be used with the HS-NCM:
* Power for the HS-NCM for use with 10th Edition panels is provided via the NUP connection on the FACP itself or an external UL/ULC listed power
supply.
† Power for the HS-NCM for use with UL 8th Edition panels must be provided by a 24 VDC UL/ULC listed power supply.
*
The following revisions
of the UL 10th edition panels require a 24 VDC UL/ULC listed power source to power the HS-NCM and cannot be pow-
ered via the panel's NUP port
* The revision and assembly name can be found on the fire panel's circuit board.
† NUP Port connections are still required for communication between the HS-NCM and the fire panel. TX, RX, and GND connections must be used for
NUP connections.
‡ If TB1 is utilized to power the HS-NCM, a UL Listed, Regulated, Power Limited 24VDC power source is required
WARNING
Adhere to the following To Avoid Permanent Damage:
UL 10th Edition
• NFS2-3030
• NFS2-640
• NFS-320
• NCA-2
• DVC-EM
• ONYXWorks
• NCD
• N16E/N16X
:
• NFS-320
• NFS2-640
• NFS2-3030
• N16E/N16X
• DVC-EM
• DVC
• NCA-2
High-Speed Network Communications Module
Product Installation Document
PN 54014:C1 12/15/2020 ECN: 151329
*
UL 8th Edition
• NFS-3030
• NFS-640
• NCA
CPU2-640PCB Revision E or older
CPU2-640PCB Revision E or older
CPU2-3030PCC Revision I or older
Core/PMB PCB
DVC-EMPCB Revision F or older
DVC-PCA All Revisions
NCA-2PCC Revision I or older

Advertisement

loading

Summary of Contents for Honeywell Notifier NFS2-3030

  • Page 1 High-Speed Network Communications Module Product Installation Document 12 Clintonville Road PN 54014:C1 12/15/2020 ECN: 151329 Northford, CT 06472-1610 USA 800-289-3473 • FAX 203-484-7118 www.notifier.com WARNING Adhere to the following To Avoid Permanent Damage: When installing a HS-NCM (High-Speed Network Communications Module) on high-speed networks and workstations, adhere to the following to avoid permanent damage: •...
  • Page 2 NOTE: All wiring connections are supervised and power limited. One HS-NCM can provide network communication for up to two nodes (including fire alarm control panels and network annunciators). Per UL 864 10th Edition, the HS-NCM uses Active Multiplex Type 3 Communication. The HS-NCM can also be configured as a high-speed repeater for applications requiring distances beyond the specified limits between two nodes.
  • Page 3 Network Communications Module for Fiber Channel A Fiber Module Channel B Fiber Module (Multi-mode or Single-mode*) (Multi-mode or Single-mode*) (HS-NCM-MF, HS-NCM-SF, HS-NCM-MFSF) • Supports fiber-optic medium Connections • NFPA Class B or Class X operation • Data is immune to all environmental noise •...
  • Page 4 3 The Network Communications Module for Wire/Fiber (HS-NCM-WMF, HS-NCM-WSF, HS-NCM-WMF-2 and HS-NCM-WSF-2) • Supports twisted-pair wire and fiber-optic medium NFPA Class B or Class X operation • Allows wire and fiber-optic nodes to communicate as one network • Fiber type: •...
  • Page 5 4 SFP Adapter Module Top View Bottom View Shield pin wired to chassis ground. EF LED Ground Fault Detection Switch Figure 6 SFP Adapter Module The SFP Adapter ground fault detection switch located on the bottom of the module. Slide the switch to the right to enable ground fault detection. When the ground fault detection switch is in the ON position, the EF LED on the top of the module will be illuminated.
  • Page 6 5 HS-NCM Configuration HS-NCM configuration changes are made via the VeriFire Tools Programming Utility, version 8.2 or higher. VeriFire Tools can be connected to the HS-NCM via two different methods: • VeriFire Tools connected to any node on a network using the HS-NCM for network communication •...
  • Page 7 Select “HS-NCM Parameters”. The HS-NCM Parameters screen will be displayed listing HS-NCM defaults. HS-NCM Installation Document — P/N 54014:C1 12/15/2020...
  • Page 8 Set the HS-NCM parameters as needed and click “Update” Addresses: IP - Network address associated with the HS-NCM. Default to all zeros when in repeater mode. Not user-modifiable MAC - Factory-set identification code for the HS-NCM. Not user-modifiable. Port A Mode: For HS-NCM-MF, HS-NCM-SFand HS-NCM-MFSF: Port A Mode is not applicable for Fiber ports.
  • Page 9: Installation

    When using a HS-NCM as a repeater, refer to the following for installation limitations HS-NCM Network Node Network Node Repeater HS-NCM with HS-NCM with with SW software software v20.x Wire Wire v31.x v30.x or v20.x v31.x v30.x or V20.x v30.x or v31.x HS-NCM Network Node...
  • Page 10 Slots Insert tab of option board into slot One HS-NCM board Two HS-NCM boards of chassis, and lay the HS-NCM in CHS-4L in CHS-4L board back against standoffs. Figure 8 Mounting HS-NCM in a Chassis (CHS-4L Shown) NOTE: Install position of the HS-NCM with SFP Fiber Module. Must be installed in the top position of the CHS-4L only. 1.
  • Page 11 6.2 Interconnecting the HS-NCM-W/W-2 When wiring consecutive HS-NCM-W/W-2 boards, note that wiring may enter or exit at Port A or Port B as shown in Figure 11. HS-NCM-W/W-2 port-to-port wiring is port sensitive. Port A must be connected to Port B of the next HS-NCM-W. A HS-NCM-W may be connected to any of the fol- lowing devices: •...
  • Page 12 6.3 Interconnecting Modules NOTE: BroadR-Reach references HS-NCM-W-2 connections and VDSL references HS-NCM-W connections 6.3.1 Replacing the HS-NCM-W with the HS-NCM-W-2 When connecting the HS-NCM-W to a HS-NCM-W-2 you must use an RJ45 Ethernet cable. Refer to Figure 12, “Replacing a HS-NCM-W with a HS- NCM-W-2”...
  • Page 13 6.3.2 Expanding an existing HS-NCM-W Network with the HS-NCM-W-2 When connecting the HS-NCM-W to a HS-NCM-W-2 you must use an RJ45 Ethernet cable. Refer to Figure 13, “Expanding an existing HS-NCM-W network using the HS-NCM-W-2” Board 2 Board 1 From previous To next node node Port A BroadR-Reach...
  • Page 14 Switch Functions: Ground Fault Detection. For UL 864 applications, enable ground fault detection by setting EF switches to the ON position: SW4.1 for Channel A, and SW4.2 for Channel B. Correct configuration depends on your network design; for an explanation of design concepts, refer to the High-Speed Noti•Fire•Net™...
  • Page 15 6.4 Mixing Wire & Fiber on One Network In some networks, it may be necessary to mix twisted-pair wire and fiber-optic cable. Use a HS-NCM-WMF/WMF-2 or HS-NCM-WSF/WSF-2 as an interface between wire and fiber. Fiber ports are not polarity sensitive. However, port-to-port wiring for the HS-NCM wire connections are polarity sensitive. When converting from a wire to fiber network, it may be necessary to change the port designation for the wire connection on the HS-NCM-WMF/WSF/WMF-2/WSF-2.
  • Page 16: Diagnostic Indicators

    6.5.2 HS-NCM-W-2 Applications Wire Type/ Gauge Maximum Distance Belden 5320UJ 18AWG, twisted-pair, unshielded FPL 1900ft (579 m) Belden 522OUZ 16AWG, twisted-pair, unshielded FPLR-CIC 1000ft (305.8 m) Belden 532OUM 18AWG, twisted-pair, unshielded FPLR-CI 1000ft (305.8 m) Comtran 8696 18AWG, twisted-pair, unshielded FPLR 1000ft (305.8 m) Table 5 Maximum Distance for Approved Cables Genesis 4050 18AWG, twisted-pair, unshielded FPL...
  • Page 17 LED Indicator LED Description LED Color LED State Onboard +3.3V Power Green On steady when power is applied. If off, check the power wiring or the NUP connection. PWR FAIL Onboard Power Tolerance Yellow Normally Off. On steady when on-board power supply is out of tolerance. Contact Customer Service for replacement.
  • Page 18: Supplemental Documentation

    This product contains software provided by third parties. Refer to document #LS10125-000GE-E for software disclosure information. Visit www.notifier.com for more information and to view respective licenses: Honeywell-branded products do not necessarily use all of the third-party software packages as referred in the web link. HS-NCM Installation Document — P/N 54014:C1 12/15/2020...