Symbol
Name
S7
ADU-TR2-SNR
ADU entrance sensor
S8
SFB-EMP-SNR
Bypass paper sensor
S9
2ND-FEED-SNR
2nd transport sensor
S10
CST1-NEAR-EMP-SNR
1st drawer paper stock sensor
S11
CST1-TRY-SNR
1st drawer tray-up sensor
S12
CST1-EMP-SNR
1st drawer empty sensor
S13
CST2-NEAR-EMP-SNR
2nd drawer paper stock sensor
S14
CST2-TRY-SNR
2nd drawer tray-up sensor
S15
CST2-EMP-SNR
2nd drawer empty sensor
S16
1ST-FEED-SNR
1st transport sensor
S17
RGST-SNR
Registration sensor
S18
REV-SNR
Reverse sensor
S19
TEMP/HUMI-SNR
Temperature/humidity sensor
S20
PLTN-SNR1
Platen sensor-1
S21
PLTN-SNR2
Platen sensor-2
SW1
MAIN-SW
Main power switch
SW2
FRNT-COV-INTLCK-SW
Front cover interlock switch
SW3
ADU-INTLCK-SW
ADU interlock switch
© 2015 TOSHIBA TEC CORPORATION All rights reserved
Function
Detecting the transporting paper at
automatic duplexing unit entrance
section
Detecting presence/absence of paper
on the bypass tray
Detecting the transport paper and
jamming fed from the 2nd drawer or
PFP/LCF
Paper amount detection in the 1st
drawer
Position detection of the lifting tray of
the 1st drawer
Paper presence/absence detection in
the 1st drawer
Paper amount detection in the lower
drawer
Position detection of the lifting tray of
the 2nd drawer
Paper presence/absence detection in
the 2nd drawer
Detecting the transporting paper and
jamming fed from the bypass, drawer,
ADU
Detecting the paper transport at the
registration roller section
Detecting the transporting paper at
the reverse section
Detecting the temperature and
humidity of the outside air taken into
the equipment
Detecting the opening/closing status
of the platen cover or RADF
Detecting the opening/closing status
of the platen cover or RADF
Turning ON/OFF of the equipment
Supplying or shutting off AC power to
the switching regulator
(voltagegenerating circuit interlocked
with these covers) according to the
opening/closing status of the front
cover (Cover open: Shut off)
Supplying or shutting off AC power to
the switching regulator
(voltagegenerating circuit interlocked
with these covers) according to the
opening/closing status of the
automatic duplexing unit (Cover
open: Shut off)
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
3 - 13
Remarks
P-I
Fig. 3-7
35-15
Fig. 3-8
Fig. 3-9
35-15
Fig. 3-10
18-6
Fig. 3-10
16-18
Fig. 3-10
16-18
Fig. 3-10
16-18
Fig. 3-10
16-18
Fig. 3-10
16-18
Fig. 3-10
16-18
Fig. 3-7
21-14
Fig. 3-8
Fig. 3-7
21-14
Fig. 3-8
Fig. 3-8
34-2
Fig. 3-6
4-16
Fig. 3-3
15-13
Fig. 3-3
15-13
Fig. 3-4
4-3
Fig. 3-4
1-11
Fig. 3-4
5-18
OUTLINE OF THE MACHINE
3

Hide quick links: