[F124] Language DB damage error
Classification
Other service call
Check item
Setting
[F130] Invalid MAC address
Classification
Other service call
Check Item
SYS board
Replacement part
SYS board
[F131] Error due to damage to filtering setting file
Classification
Other service call
Check Item
Setting
Replacement part
HDD
[F140] ASIC format error
Classification
Other service call
Check Item
SYS board
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
Login after the startup fails in any starting mode because
language management database is corrupted.
Delete the journal file: [5] + [C] + [START] -> 4. Initialize DB -
> 3. Language DB
If the recovery is still not completed, reinstall the master data
and application program.
 P. 11-5 "11.2.2 Update procedure"
This error occurs when the top 3 bytes of the MAC address is
not "00" "80" "91".
Replace the SYS board.
The filtering function is not working properly due to the
damage to the file for the filtering setting.
1. Check the bad sector of the HDD (08-9072). If the result is
"NG", replace the HDD.
Notes:
It may take more than 30 minutes to finish the
checking.
2. Perform [3] + [C] + [POWER] -> [3], and then reinstall the
HDD software.
Notes:
User data will be deleted when [3] + [C] + [POWER] ->
[3] is performed.
Error content
ASIC formatting fails or memory acquiring fails when software
is formatted
Connector check
Board check
© 2015 TOSHIBA TEC CORPORATION All rights reserved