Toshiba e-STUDIO2008A Service Manual page 845

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2008A:
Table of Contents

Advertisement

[71AC] File save error during certificate acquisition from SCEP server
Classification
Maintenance error
Check item
Setting
[71AD] Failed SCEP operation
Classification
Maintenance error
Check item
Setting
[71B0] Software package file decryption failure
Classification
Maintenance error
Check item
Setting
[71D0] Factory Default Failure
Classification
Maintenance error
Check item
Setting
[71F1] Unsuccessful Creation of Clone File
Classification
Maintenance error
Check item
Setting
© 2015 TOSHIBA TEC CORPORATION All rights reserved
File save error occurred during certificate acquisition from
SCEP server.
File saving failed for some reason. If the error still occurs after
rebooting the equipment, start up using the following
procedure:[3] + [C] + [START]  3. HDD formatting 
Reinstallation of software or HDD replacement
SCEP operation is failed
Check SCEP server and the SCEP setting on the TopAccess
menu as follows:
[Administration] > [Security] > [Certificate Management] >
SCEP (Automatic)
Software package file decryption failed.
Software package file may have a problem or may be
corrupted. Check the software package file and then
reattempt the installation.
Factory default setting failed.
Restart the equipment and then retry.
The creation of a clone file failed.
Check if there is enough capacity in the HDD and the USB media
and then retry the creation.
8 - 307
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A