Turning Up a Node
DLP-G315 Installing Fiber-Optic Cables From the 32WSS/32DMX and 32MUX-O/32DMX-O Cards to the Standard Patch Panel Tray
Step 4
Route the MPO cable slack through the patch panel tray as necessary.
Caution
Step 5
While facing the front of the patch panel, at the rear side of the patch panel, plug the eight LC-connector
fan-out cables on the MPO cable into their corresponding connectors on the bottom row of the patch panel.
You should plug the fan-out cables from left to right (as you face the patch panel), following the numbers
tagged (1 through 8) on the cables.
The following figure shows the patch panel connectors from the rear of the patch panel tray.
When you close the patch panel tray, the cables must not be pinched, and the cable bend radius
must be equal to or greater than the minimum radius that is recommended in your site specifications.
As you route each cable through the patch panel tray, make sure that adequate cable slack remains.