Technical data
3.5.2 Pressure Sensor Type 17002
Data
External thread (internal model)
Usable thread length (internal model)
Measuring range
... 7 bar abs.
0.9
The pressure sensor is available as both an external and
internal model. Further details can be found under
www.elster-instromet.com or chapter "Assembly,
Connection and Putting into Operation".
3.6
Temperature sensor
Data
Measuring range
Measurement uncertainty
Installation length
3.7
Digital inputs
3.7.1 LF pulse and signal inputs
The maximum counting frequency of the digital inputs can be adjusted
using the "enSuite" software. The limit values specified for frequency and
duration shall only apply if the so-called "software debounce" has been
switched off.
The software debounce is activated ex-works to suppress interference
pulses and therefore restrict safe readings to 2 Hz.
If the software debounce is parameterized to a frequency
higher than 2 Hz, then it may lead to counting errors
caused by electromagnetic interference under certain
circumstances.
Value
Unit
M12 x 1.5
approx. 10
mm
Overload capacity
10 bar abs.
Value
Unit
-30 ... +60
°C
max. ± 0.1
%
50
mm
25