Honeywell EK280 Operating Instructions Manual page 90

Volume conversion device
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

90
Message
p Alarm Lim.
K-val. error
z-fact. err.
Vm-Alarm
Vm-Inp.Alarm
T Inp. error
p Inp. error
b) Warnings:
Data restore
Meaning, action
The measured gas pressure is outside the permissible
limits.
The limit values can be changed when putting the
device into operation in the presence of a calibration
officer (see chapter 5.3.1.11, page 55)
The compressibility ratio factor could not be calculated
as no valid real gas factor could be determined.
The real gas factor could not be calculated.
At least one of the gas analysis values Ho.n, CO2, H2,
rhon, is outside the permissible range.
No volume was recorded at the used input for
conversion. (The automatic switchover of the pulse
transducer to a second pulse transducer is not
configured acc. chapter 5.2.1.4.).
No volume at measurement conditions was recorded at
the connected encoder on input 1 for 20 seconds (with
ext. power supply) or for two measurement cycle + 1
second (battery powered).
The gas temperature cannot be measured due to a
fault.
Please contact the Elster support (see chapter 1.3
"Customer service").
The gas pressure cannot be measured due to a fault.
Please contact the Elster support (see chapter 1.3
"Customer service").
The batteries of the EK280 are intermittently dropping
out. As a result of this, the time has not changed and no
measurement and volume conversion have happened.
However, all data is available.
This message appears when old batteries are removed
before connecting the new ones (see chapter 7.2).
Proceed with the help of the configuration program
"enSuite":
Set the time of the EK280
Delete the status register
Faults