Assembly, Connection and Putting into Operation
To change the cp values for output 1 or output 2, move the cursor to the
"Serv." register and go to "cp.O1" (for output 1) or "cp.O2" (for output 2) via
the following path:
Serv.
or
Serv.
Press the ENTER button . The cp value will flash.
Move the cursor using the arrow keys  or  to the digits and
change these using the arrow keys  or .
Press the ENTER button to confirm the set value. The input value
can be deleted by pressing the ESC button.
Aside from the settings described here, a range of other
functions can be configured for the outputs, e.g. high
frequency or time-synchronous pulses.
A complete description can be found in the EK280 Application
Manual that can be downloaded under www.elster-
instromet.com.
5.3.1.14 Setting the daylight saving time
Move the cursor to the "Serv." register and to the "MdTim" value
(daylight saving mode) via the following path:
Serv.
Press the ENTER button.  The set value will start to flash.
Change the value using the arrow keys  or :
MdTim
CEST off
CEST autom.
CEST manual
Press the ENTER button to confirm the set value. The input value
can be deleted by pressing the ESC button.
Outputs
Output 1
Outputs
Output 2
Date and Time
Meaning
No switchover to daylight saving time
Automatic switchover to daylight saving time
(CEST = Central European Summer Time)
The start and end of daylight saving time is
configured by the control center every year.
cp.O1
cp.O2
MdTim
57