Connect Outputs Of The Ek280 - Honeywell EK280 Operating Instructions Manual

Volume conversion device
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

Assembly, Connection and Putting into Operation

5.2.6 Connect outputs of the EK280

The cable core diameter for the connection to the EK280
outputs is 0.33 ... 2.5 mm
Different downstream devices can be connected to the
digital outputs of the EK280. The outputs are preconfigured
for this purpose (see chapter 5.3.1.13).
Fig. 18
3. If necessary, adjust the cp value (pulse contact) for the pulse outputs as
described in chapter 5.3.1.13.
5.2.6.1
Electrical insulation of the outputs
In standard cases, all negative poles of the outputs are electrically
connected to the motherboard.
For special applications, i.e. switching a positive pole, each output can be
electrically separated from the motherboard and from the other outputs.
CAUTION!
Reduced battery life
Activating the electrical insulation of outputs reduces the
battery life when in battery mode!
It is then impossible to give a reliable prediction of the
remaining battery life.
2
.
1. Connect the downstream device to the
corresponding digital outputs (terminals
"DA1" to "DA4") of the EK280 (p. Fig.
18).
2. Terminal covers are provided in the bag
of accessories to seal the output
terminals. If required, these should be
screwed over the connected terminals
and a seal should then be bonded to the
fastening screw (see chapter 5.3.2).
45