Faults
Message
Outp.1 Error
Outp.2 Error
Outp.3 Error
Outp.4 Error
I1-Warning
I2 Pulse cmp
W Warn Lim.
Vb Warn Lim.
Vc Warning
Qm Warn Lim. The actual flow rate (gas flow rate) is outside the set
T Warn Lim.
p Warn Lim.
Meaning, action
There should be more pulses being emitted from the
specified output than are permitted under its configured
settings.
In order to eliminate the cause of the problem, you can
use the configuration program "enSuite" to either:
reduce the cp value of the output
or increase the output frequency.
In both cases, the change must be aligned with the
connected device.
The encoder could not be read at the end of the
measurement period. The flow recording at this point is
invalid.
In the pulse comparison, e.g. between input 1 and input
2, the deviation was too high.
The displayed value is outside the set warning limit
values.
The warning limits can be adjusted using the
configuration program "enSuite".
The monitored volume at base conditions consumption
value (standard: hourly consumption) is outside the set
warning limit values.
The monitored values and the warning limits can be
adjusted using the configuration program "enSuite".
The parameters for the corrected volume at
measurement conditions are not sorted in ascending
order or one of the values is outside the permissible
limits.
warning limit values. The warning limits can be adjusted
using the configuration program "enSuite".
The measured gas temp. is outside the warning limit
values.
The warning limits can be adjusted using the
configuration program "enSuite".
The measured gas pressure is outside the warning limit
values.
The warning limits can be adjusted using the
configuration program "enSuite".