Pressure Sensor; Ct30 Type Pressure Sensor - Honeywell EK280 Operating Instructions Manual

Volume conversion device
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

24
3.5

Pressure sensor

3.5.1 CT30 Type Pressure Sensor

Data
External thread
Usable thread length
3.5.1.1
Absolute pressure ranges
Measuring range
0.7 ... 2 bar abs.
0.8 ... 5 bar abs.
1.4 ... 7 bar abs.
2.0 ... 10 bar abs.
2.4 ... 12 bar abs.
4 ... 20 bar abs.
6 ... 30 bar abs.
8 ... 40 bar abs.
14 ... 70 bar abs.
16 ... 80 bar abs.
These pressure sensors are available as both an external
and internal model.
Further details can be found under www.elster-
instromet.com or chapter "Assembly, Connection and
Putting into Operation".
3.5.1.2
Relative pressure ranges
Measuring range
... 7 bar rel.
1.4
... 20 bar rel.
4
... 80 bar rel.
16
These pressure sensors are only available as an externally
connected model and can only be used as a second
pressure sensor for non-metrological measurements.
Further details can be found under www.elster-
instromet.com or chapter "Assembly, Connection and
Putting into Operation".
Value
M12 x 1.5
approx. 10
Overload capacity
18 bar abs.
25 bar abs.
25 bar abs.
40 bar abs.
40 bar abs.
40 bar abs.
60 bar abs.
60 bar abs.
105 bar abs.
105 bar abs.
Overload capacity
40 bar rel.
40 bar rel.
105 bar rel.
Technical data
Unit
mm

Advertisement