Receipt Of Delivery; Type Designation Code - Honeywell NX series User Manual

Constant and variable torque variable speed drives for induction motors
Hide thumbs Also See for NX series:
Table of Contents

Advertisement

3.

RECEIPT OF DELIVERY

NX frequency converters have undergone scrupulous tests and quality checks at the factory before they
are delivered to the customer. However, after unpacking the product, check that no signs of transport
damages are to be found on the product and that the delivery is complete (compare the type designation of
the product to the code below, Figure 3-1.
Should the drive have been damaged during the shipping, please contact primarily the cargo insurance
company or the carrier.
If the delivery does not correspond to your order, contact the supplier immediately.
In the small plastic bag included in the delivery you will find a silver Drive modified sticker. The purpose of
the sticker is to notify the service personnel about the modifications made in the frequency converter.
Attach the sticker on the side of the frequency converter to avoid losing it. Should the frequency converter
be later modified (option board added, IP or EMC protection level changed), mark the change in the sticker.
3.1

Type designation code

A 2 H 1
NXS 0000
V 3
5
Figure 3-1. NX type designation code
Note: Ask factory for other possible installation combinations.

RECEIPT OF DELIVERY

S
A1A20000C3
Option boards; each slot is represented by two characters where:
A = basic I/O board, B = expander I/O board,
C = fieldbus board, D = special board
Hardware modifications;
S = standard
V = varnished boards
Brake chopper
0 = no brake chopper
1 = internal brake chopper
2 = internal brake chopper and resistor
C = fulfils requirements of category C1 of standard EN61800-3 (2004),
1st environment and rated voltage less than 1000V
H = fulfils requirements of category C2 of standard EN61800-3 (2004),
fixed installations and rated voltage less than 1000V
L = fulfils requirements of category C3 of standard EN61800-3 (2004),
2nd environment and rated voltage less than 1000V
T = fulfils standard EN61800-3 (2004) when used in IT networks
N = No EMC emission protection. An external EMC filter needed
Enclosure class:
0 = IP00 (FR9 only), 2 = IP21 (Nema 1), 5 = IP54 (Nema 12)
Control keypad:
A = standard (alpha-numeric)
B = no local control keypad
F = dummy keypad
G = graphic display
Voltage range:
2 = 208–240Vac, 5 = 380–500Vac, 6 = 525–690Vac (All 3-phase)
Phase 1 or 3
Voltage
Nominal current (low overload)
0007 = 7 A, 0022 = 22 A, 0205 = 205 A etc.
Product range: NXS = standard, NXP = high-performance
3
13(110)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents