3.2.11 Rotate transmitter housing

Once installed, the transmitter housing can be rotated to the desired orientation by
loosening the two setscrews on the sensor housing and then rotating the sensor
electronics with respect to the process connector.

3.2.12 Secure the probe

In tanks with turbulence, it may be necessary to secure the probe to the tank to prevent
probe damage, or contact with the tank wall. Depending on probe type, different methods
can be used. For wire probes with end weights, the end weight has an internal M10x1.5
thread. This thread can be used to attach various mounting hardware (customer supplied).
Alternatively the weight can be removed and a clamp can be used. See
Revision 7
WARNING: Rotating the electronics housing with respect
to the sensor housing may damage the sensor electronics.

Figure 3-32: Rotate transmitter housing

SLG 700 SmartLine Level Transmitter User's Manual
Figure 3-33.