With the Transmitter in Analog mode, you can observe the output on an externally-
connected meter or on a local meter.
7. Select the Yes button. Observe the output current at the percentage you selected in Step 5.
8. To view the monitor display, navigate back from the LOOP TEST display, and select the
MONITOR display. A Confirm popup will be displayed.
9. Select Yes to continue. This concludes the Startup procedure
The example diagram does not display the 8 pin interface connector.
The interface connector connects the Display Module to the Communication
Note:
Module. If this is not in place the display will not receive power.
Note:
The example diagram refers to a HART transmitter, the following process is
the same for FF.
5.3.3 Replacing the Terminal Block
Refer to Installing the Terminal Block Module, Document #34-ST-33-64.
5.3.4 Replacing the Display Assembly
Refer to Installing the Display Module, Document #34-ST-33-65.
5.3.5 Replacing the Communication Module
Refer to Installing the Communication Module, Document #34-ST-33-69.