TM
FM Approvals
Certificate #
FM16US0117X
Page 148
Explosion proof with
intrinsically safe probe:
Class I Division 1, Groups A, B, C,
D with Intrinsically safe probe
Class 1, Zone 0/1 AEx ia/d IIC
Ga/Gb T4
Dust Ignition Proof with
intrinsically safe probe:
Class II, Division 1, Groups E, F,
G, T4 with Intrinsically Safe Probe
Zone 21 AEx tb IIIC Db T95
Probe : Zone 20 AEx ia IIIC Da
o
T95
C
Intrinsically Safe:
Class I, II, III, Division 1, Groups A,
B, C, D, E, F, G, T4
Class l, Zone 0, AEx ia IIC T4 Ga
Non-incendive with intrinsically
safe probe:
Class I, II, III, Division 2, Groups A,
B, C, D, F, G, T4 with Intrinsically
Safe Probe
Class l, Zone 2, AEx nA IIC T4 Gc
Class l, Zone 2[0], AEx nA[ia Ga]
IIC T4 Gc (Remote version only.)
Enclosure: Type 4X/ IP66/ IP67.
Dual Seal in accordance with
ANSI/ISA 12.27.01
SLG 700 SmartLine Level Transmitter User's Manual
All
o
C
4-20 mA / HART
FOUNDATION
Fieldbus / FISCO
4-20 mA / HART
FOUNDATION
Fieldbus / FISCO
All
Note 1
Note 2
Note 2
Note 1
Note 1
All
Revision 7