Table 4-28 Error Messages - Honeywell DR4300 Product Manual

Circular chart recorder
Hide thumbs Also See for DR4300:
Table of Contents

Advertisement

4.5.1.4 Diagnostic Error Messages
Recorders with displays run background tests as described in Section 8 – Troubleshooting and Pen
Alignment of Recorders with Display to verify data and memory integrity. If there is a malfunction, an error
message will blink in the lower display. If more than one self-diagnostic test fails, the display will cycle
through the appropriate error messages.
A list of background test error messages is in Table 4-28.
If any of these error messages are displayed, refer to Section 8 for information on correcting the problem.
In addition, an error message will be displayed if the operator tries to run a setpoint program in which the
number of the ending segment is lower than the segment number of the start segment. See Appendix C for
details.
Prompt
CALERR
CFGERR
EEFAIL
FAILSF
INP FL
INPRNG
P1 ERR or
P2 ERR
RAMTST
SEGERR
ATTENTION
In addition to error messages, the recorder will display special status messages when optional
features are active.
• If the lower display flashes "TUNING", the recorder is in the process of automatically
determining tuning parameters using the Accutune II feature described in Appendix D.
• If the lower display flashes "RUN n" or "HOLD", the recorder is executing setpoint program "n"
as described in Appendix C, and the run or hold action was initiated locally.
• If the lower display flashes "run n" or "hold", the recorder is executing setpoint program "n",
and the run or hold action was initiated remotely.
4/00

Table 4-28 Error Messages

Indicates failure of the calibration test.
Indicates failure of the configuration test.
Unable to write to nonvolatile memory
Failsafe value being used as output
Two consecutive failures of input integration
Input out-of-range
Indicates error on channel other than the one on display.
Indicates failure of the RAM test.
Indicates that the number of the setpoint program's end segment is lower
than the segment number of the start segment.