Appendix A. Specifications and References

Physical and Operational Specifications

This section provides physical and operational specifications for the SVI II ESD. Specifications are
subject to change without notice.
Operating Temperature Range
Storage Temperature Limits
Temperature Effect
Supply Pressure Effect
Relative Humidity
Humidity Effect
Insulation Resistance
MTBF
Electromagnetic Compatibility
Electrostatic
Fast Transient Burst
Vibration Influence
Measured at SVI II ESD Housing
© 2016 General Electric Company. All rights reserved.
Table 13 Environmental Specifications
-40 °F to 185 ° F (-40 °C to 85 °C)
-58 °F to 200 °F (-50 °C to 93 °C)
< 0.005% / °F typical; -40 °F to 180 °F (< 0.01% / ° C typical; -40 ° C to 82 °C)
0.05% per psi (.73% per bar)
10 to 90% non-condensing
Less than 0.2% after two days at 104 °F (40 °C), 95% Relative Humidity.
Greater than 10 G Ohms at 50% RH.
49 years based on MIL handbook calculation for electronic parts and field
data on mechanical parts
Electrostatic discharge — No effect with contact discharge level of 4KV
and air discharge level of 8 KV
(IEC 1000-4-2)
Radio frequency interference — Less than 0.2% at 10 V per meter (EN
50140)
No effect at 2 KV (Coupling clamp IEC 1000-4-4).
4 mm at 5 - 15 Hz - Negligible
2 G at 15 - 150 Hz Less than 2% of span
1 G at 150 - 2000 Hz - Less than 2% of span