GE ATS1290 Instruction Manual

Point id dgp
Hide thumbs Also See for ATS1290:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Quick Links

ATS1290
Point ID DGP
Fig. 2
Fig. 1
Fig. 3
Y
Q
X
X
DGP
Control Panel
Z
DGP
R
DGP
DGP
Control Panel
Control Panel
Control Panel
Lumped
Distributed
Star
Remote DGP
Fig. 4
© 2004 GE Security B.V.
1052285
All rights reserved
02/2005

Advertisement

loading

Summary of Contents for GE ATS1290

  • Page 1 ATS1290 Point ID DGP Fig. 2 Fig. 1 Fig. 3 Control Panel Control Panel Control Panel Control Panel Lumped Distributed Star Remote DGP Fig. 4 © 2004 GE Security B.V. 1052285 All rights reserved 02/2005...
  • Page 2: Available Menus

    Available menus Point ID DGP 1-DGP Status 0-Exit, Menu: Operating *=-,#=+,0=Exit Dev:16 A:0 T:0 *=-,#=+,0=Exit DGP1 I:17-32 O:17-32 *=-,#=+,0=Exit V-bus: 12,7 Vdc *=-,#=+,0=Exit I-bus: 3 mA *=-,#=+,0=Exit 2-Device Status 0-Exit,Menu: 17/0,PIR,T0 Input No: 17/0, Normal *=-,#=+,0=Exit 3-Device Settings 0-Exit,Menu: 17/0,PIR,T0 Input No: 17/0,Loc1:0 *,Value:...
  • Page 3 NTRODUCTION terminal (see & ). The bus loop does not need special termination. The ATS1290 is an interface between the ATS LAN-bus and a Point ID bus (GE proprietary Point ID protocol). The PID- PID – BUS ( ABLE OPOLOGY...
  • Page 4 Point ID devices need to be recognised by the ATS1290 Point ID DGP before the device will be able to transfer status information or can be configured by the Point ID DGP. To facilitate this, the ATS1290 Point ID DGP has a jumper Star (distance Q) (JP2, fig 1 ).
  • Page 5 8) to toggle the bit between 0 and 1. See the device manual 17/0,PIR,T0 for information regarding the available settings. Input No: Press ENTER to move to the next location. 4. Reset settings Six categories are defined in the system which will be Shows a selection list as in menu 2.
  • Page 6 DGP adressable NTRODUCTION NSTALLATION DE PERIPHERIQUES ADRESSABLES Le DGP ATS1290 fait office d’interface entre le bus RS485 CON2 ( . 1, ONNEXIONS VOIR FIG de la centrale ATS et un bus point ID (protocole point ID, Connexion aux périphériques adressables. Cette propriété...
  • Page 7 (ATS4/3/2000 d’un tournevis pendant quelques secondes permet de ou ATS1201) et celle au niveau du ATS1290. Pour éviter démarrer la reconnaissance des périphériques. Tout réglage une telle chute de tension, effectuez une des opérations supplémentaire lors de la configuration d’un périphérique...
  • Page 8 1 DGP + extension : gère 32 entrées et 16 sorties Liste des catégories 2 adresses DGP : gère 32 entrées et 32 sorties. Dans ce cas, 2 DGPs seront scrutés dans la centrale. Cet ATS1290, MISC Divers + le DGP suivant qui sera « standard ».
  • Page 9 Caractéristiques techniques Alimentation (CON1) 10,5 – 13,8 V 53 mA (aucun détecteur PID connecté) Courant d’alimentation (à 13,8 V ± 5 %) Alimentation ID de point (CON2) 9,9 – 13,2 V +données et impulsions supplémentaires Alimentation de sortie ID de point maximale 154 mA (512 unités de charge max.) (13,2 V ±...
  • Page 10 DIP-switches in zoals aangegeven in figuur 2. Opmerking: De minimale werkspanning van de Point ID-bus is 9,5 VDC (gemeten op CON1 + en - van de ATS1290 Point LED’ ID DI). Dit is 1 VDC lager dan de spanning van een bijna Deze LED knippert om aan te geven dat er lege accu (10,5 VDC).
  • Page 11 ATS1290 Point ID DI. Externe DI Om dit te realiseren is de ATS1290 Point ID DI uitgerust met Het is mogelijk dat er een spanningsverlies optreedt een jumper (JP2, Fig. 1 ). Als u deze jumper enkele...
  • Page 12 Met ENTER Hier kunt u informatie ophalen over de status van de of MENU kunt u door het modulebereik stappen. Druk op 0 ATS1290. gevolgd door ENTER om af te sluiten. Gebruik de ENTER-toets om door de verschillende 3.
  • Page 13 Technische specificaties Voedingsspanning (CON1) 10,5 – 13,8 V 53mA (zonder aangesloten Point ID-modules) Stroomverbruik (bij 13,8 V ± 5%) Point ID-aansluitspanning (CON2) 9,9 – 13,2V    + aanvullende data-pulses 154mA (max 512 eenh. van belasting) Max Point ID-uitgangsstroom (bij 13,2V ±...
  • Page 14 Concentratore Point ID NTRODUZIONE NSTALLAZIONE DEI DISPOSITIVI OINT L’ATS1290 è un’interfaccia tra il bus dati dell’ATS e un CON2 ( . 1, . 3) ONNESSIONI VEDERE FIG E FIG bus Point ID (protocollo Point ID proprietario di GE). Il Connessione a tutti i dispositivi Point ID. Richiede concentratore PID (Point ID) fornisce comunicazioni la connessione di un terminale + e di un terminale –.
  • Page 15 Per semplificare questa operazione, il concentratore operazioni: Point ID ATS1290 dispone di un ponticello (JP2, Fig. 1 ). Cortocircuitando il ponticello con un cacciavite per 1. Utilizzare un alimentatore aggiuntivo presso il alcuni secondi, si avvierà la modalità di acquisizione concentratore.
  • Page 16 ENTER. Per 1. Status [Stato] scorrere i dispositivi, premere ENTER o MENU. Per uscire, Visualizza le informazioni relative allo stato dell’ATS1290. premere 0 ENTER. Utilizzare il tasto ENTER per spostarsi tra le diverse 3.
  • Page 17 Specifiche tecniche Alimentazione (CON1) 10,5-13,8 V 53 mA (nessun dispositivo PID collegato) Corrente di alimentazione (a 13,8 V ± 5%) Alimentazione Point ID (CON2) 9,9-13,2V    + impulsi dati aggiuntivi  Corrente massima di uscita Point ID 154 mA (carico unitario massimo 512) (a 13,2 V ±...
  • Page 18 . 4) NTRODUKTION ABELTOPOLOGI SE FIG ATS1290 er et interface mellem ATS bussen og en Point I princippet har PID-bussen fri topologien. ID-bus (protokollen GE proprietary Point ID). PID-DGP’en I figur 4 er der vist flere forskellige topologier: muliggør totrådet tovejskommunikation med op til 32 •...
  • Page 19 Alle yderligere indstillinger vedrørende konfiguration af enheden er enten tilgængelige via jumper-/dipswitchindstillingerne eller via en konfigurationsmenu, som er en del af ATS1290- programmeringsmenu. Yderligere oplysninger om de enkelte Ekstern DGP instillinger for en PID-enhed finder du i vejledningen til den pågældende enhed.
  • Page 20 Der er defineret 6 kategorier i systemet, som automatisk Tryk på zonenummer og derefter på ENTER for at registreres af ATS1290 DGP’en. For hver kategori kan nulstille indstillingen for en bestemt enhed. Du skal der være flere typer, disse angives i en undergruppe.
  • Page 21 PID- LAITTEEN JA VÄYLÄN KAAPELITAVAT KATSO KUVA kaksisuuntaisen kahden johtimen yhteyden 32 PID- laitteeseen, joilla kullakin on oma osoite. ATS1290 on Väylän topologialle ei periaatteessa ole rajoituksia. tarkoitettu liitettäväksi olemassa olevaan ATS-laitteiden Tässä on esitetty useita tapoja (katso kuva 4).
  • Page 22 Kaukokeskitin oikosulkupalan/DIP-kytkinten asetuksilla tai ATS1290- keskittimen ohjelmointivalikon kautta. Lisätietoja laitteen Verkkosyöttöön liitetyn laitteen (ATS4/3/2000 tai ATS1201) käytettävissä olevista asetuksista on laitteen normaalijännitteen (13,8 VDC) ja ATS1290-keskittimen käyttöoppaassa. välillä voi esiintyä jännitehäviöitä. Voit estää tämän tekemällä jommankumman seuraavista: ATS1290- KESKITTIMEN OHJELMOINTIVALIKKO 1.
  • Page 23 Keskittimen käyttöjännite. ohjelmointipaikkoihin. MENU-näppäimellä voit siirtyä arvo- ja binäärimuotoisen esityksen välillä 1.5 Virta Jos käytät arvomuotoista esitystapaa, syötä arvo väliltä PID-väylän virrankulutus. 0 ja 225. Jos taas käytät binäärimuotoista esitystapaa, 2. Osoitelaitteen tila (Device status) vaihda yksikön tilaa välillä 0 ja 1 näppäilemällä yksikön numero (1–8).