Nokia 7210 Configuration Manual page 549

Service access switch 7210 sas-m, t, r6, r12, mxp, sx, s basic system
Hide thumbs Also See for 7210:
Table of Contents

Advertisement

7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
Table 58
down-mep
Syntax
down-mep num-resources
no down-mep
Context
configure>system>resource-profile>ingress-internal-tcam>eth-cfm
Platforms
7210 SAS-Mxp, 7210 SAS-R6, 7210 SAS-R12, 7210 SAS-Sx/S 1/10GE, and
7210 SAS-Sx 10/100GE
Description
This command enables the user to allocate more resources and increase the number of CFM/
Y.1731 Down MEPs. By default, the system allocates a single slice for use with Down MEP.
Resources from this pool are allocated towards the following:
Note: On the 7210 SAS-R6 and 7210 SAS-R12, bidirectional MIPs also use the Up MEP
resource pool.
3HE 17358 AAAB TQZZA
Number of Resources Available for ETH-CFM (Continued)
Platforms
7210 SAS-R6 and 7210 SAS-R12 (per IMM-
c)
7210 SAS-Mxp (per node)
7210 SAS-Sx 1/10GE (per node)
(standalone)
7210 SAS-Sx 1/10GE (standalone-VC)
7210 SAS-S 1/10GE (per node)
(standalone)
7210 SAS-S 1/10GE (standalone-VC)
7210 SAS-Sx 10/100GE (per node)
• down MEP on SDP binding
• on the 7210 SAS-Mxp, 7210 SAS-Sx/S 1/10GE (standalone), and 7210 SAS-Sx 10/
100GE (standalone), ingress and egress MIPs for Epipe SAPs and Epipe SDP bindings
• on the 7210 SAS-R6 and 7210 SAS-R12, ingress and egress MIPs (that is, bidirectional
MIPs) for Epipe SAPs and Epipe SDP bindings
Use subject to Terms available at: www.nokia.com
Min value
(per node)
1
1
1
2
1
2
1
© 2021 Nokia.
System Management
Max value
Default
(per node)
3
1
3
1
3
1
4
2
3
1
4
2
3
1
549

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7210 sas-mxp7210 r67210 r127210 s7210 sx7210 t

Table of Contents