Subsequent Reboot Of The Stack (With Correct Bof Present); Replacing And Upgrading A Node In A Vc - Nokia 7210 Configuration Manual

Service access switch 7210 sas-m, t, r6, r12, mxp, sx, s basic system
Hide thumbs Also See for 7210:
Table of Contents

Advertisement

Virtual Chassis
5.6.2 Subsequent Reboot of the Stack (with Correct BOF
This scenario assumes that the BOF configured on each node during the first time
boot up is saved locally and contains the VC configuration required for the node to
boot up. It also assumes that the chassis-role parameter in the bootflash is set to
standalone-vc for each node.
The following sequence occurs in the boot loader context and in the TiMOS context.
There is no user intervention required.
If both the cpm-imm nodes come up as active, which is detected by both nodes
receiving each other's VC management messages claiming themselves to be active,
the node with the higher slot number reboots itself.

5.7 Replacing and Upgrading a Node in a VC

This section describes how to:
240
Present)
• In the boot loader context, all the nodes in the VC read their bootflash and the
BOFs that are present locally, and receive their VC configuration.
• In the boot loader context, the nodes configured as cpm-imm go through a CPM
election process and the node with the lower slot number is chosen as the active
CPM. Both nodes proceed to boot up using the TiMOS image (both.tim).
• In the TiMOS context, both the cpm-imm nodes again read the BOFs that are
present locally and receive their VC configuration.
• In the boot loader context, the imm-only nodes wait to receive VC management
messages from the active CPM, when the active CPM has booted up. When the
imm-only nodes receive VC management messages that contain their MAC
address and slot number, they proceed to boot up using the TiMOS image
(both.tim). A local copy of the TiMOS image is used if it matches the version
available on the active CPM; otherwise, the imm-only nodes retrieve the newer
version from the active CPM. The imm-only nodes do not participate in the CPM
election process.
• In the TiMOS context, the cpm-imm nodes go through the CPM election
arbitration process to elect the active CPM node. The active CPM node then
initializes the chassis manager and initiates a HA reconcile process with the
standby CPM node.
• replace a CPM-IMM node or IMM-only node
• upgrade an existing IMM-only node to a CPM-IMM node
Use subject to Terms available at: www.nokia.com
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
© 2021 Nokia.
Configuration Guide
3HE 17358 AAAB TQZZA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7210 sas-mxp7210 r67210 r127210 s7210 sx7210 t

Table of Contents