System Management
falling-threshold threshold — Specifies a threshold for the sampled statistic. A single
interval seconds — Specifies the polling period over which the data is sampled and
rmon-event-type — Specifies the type of notification action to be taken when this event
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first
418
After a rising threshold crossing event is generated, another such event will not be
generated until the sampled value falls below this threshold and reaches less than or
equal the falling-threshold value.
Values
–2147483648 to 2147483647
Default
0
threshold crossing event is generated when the current sampled value is less than
or equal to this threshold, and the value at the last sampling interval was greater than
this threshold. A single threshold crossing event will also be generated if the first
sample taken is less than or equal to this threshold and the associated startup-alarm
is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be
generated until the sampled value raises above this threshold and reaches greater
than or equal the rising-threshold value.
Values
–2147483648 to 2147483647
Default
0
compared with the rising and falling thresholds.
Values
1 to 2147483647
occurs.
Values
log — An entry is made in the RMON-MIB log table for each event
occurrence. This does not create a TiMOS logger entry. The RMON-
MIB log table entries can be viewed using the show system
thresholds command.
trap — A TiMOS logger event is generated. The TiMOS logger utility
then distributes the notification of this event to its configured log
destinations which may be CONSOLE, telnet session, memory log,
cflash file, syslog, or SNMP trap destinations logs.
both — Both an entry in the RMON-MIB logTable and a TiMOS
logger event are generated.
none — No action is taken.
Default
both
created. If the first sample is greater than or equal to the rising threshold value and
startup-alarm is equal to rising or either, a single rising threshold crossing event is
generated. If the first sample is less than or equal to the falling threshold value and
startup-alarm is equal to falling or either, a single falling threshold crossing event
is generated.
Values
rising, falling, either
Default
either
Use subject to Terms available at: www.nokia.com
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
© 2021 Nokia.
Configuration Guide
3HE 17358 AAAB TQZZA