Sony SIR-1000W Instruction Manual page 96

High speed digital data recorder, channel expansion unit
Table of Contents

Advertisement

Command
MON :
Command format
OFA :
Command format
OFS :
Command format
12-6
Monitor channel selection
MON : <1><2>/[ ]
<1>: Channel expansion unit ID number <2>: Channel code
0 = Recorder
1 = Channel expansion unit 1
2 = Channel expansion unit 2
3 = Channel expansion unit 3
4 = Channel expansion unit 4
5 = Channel expansion unit 5
6 = Channel expansion unit 6
7 = Channel expansion unit 7
Related command: MON?
Auto offset setting
OFA : <1><2>/[ ]
<1>: RSV (always 0)
<2>: 0 = DC offset measurement stop and set, 1 = Offset measurement start
Related command: OFA?
DC offset setting
OFS : <1><2>...<33>/[ ]
<1>: Channel expansion unit ID number (0=Recorder)
<2><3>: CH 1 DC offset
<4><5>: CH 2 DC offset
.
.
.
<32><33>: CH 16 DC offset
The DC offset value is expressed as a 2-digit hexadecimal number.
Ex.) OFS : 000100022334500FFCE2345220034A1FB
00 : 0%
01 : 1%
10 : 16%
32 : 50%
64 : 100%
FF : –1%
CE : –50%
9C : –100%
Related command: OFS?
Contents
0 = CH 1
1 = CH 2
2 = CH 3
3 = CH 4
4 = CH 5
5 = CH 6
6 = CH 7
7 = CH 8
8 = CH 9
9 = CH 10
A = CH 11
B = CH 12
C = CH 13
D = CH 14
E = CH 15
F = CH 16