11 External Control
Functions
Interface
14
25
1
13
The SIR-1000W can be operated easily by using a TTL level control signal via the
EXT.CONT connector.
Command functions (input)
The following commands can be input to the recorder.
• Tape transport mode setting
• ID increment
Monitoring functions (output)
The following recorder states can be output.
• Loading
• Tape transport mode
• Alarm message
• BOD, EOD, EOT
Connector : Square, D-sub 25-pin
Input
: TTL level, pulse width of 100 ms or more, input by shorting pins 1 or 15 (GND)
Output
: TTL level output, sink current maximum 20 mA
Connector Pin Assignment
Pin No.
Signal name
Function
1
GND
+5V
AUXILIARY POWER SUPPLY
2
3
BOD
4
EOD
5
ALARM
ALARM MESSAGE
6
EOT
LOADING
LOADING
7
8
OPAUSE
PAUSE
9
OREC
OSTOP
10
11
OFWD
12
OFF
13
OREW
Note
ALARM : Output when any one of low DC voltage, recording/playback error, dew
condensation or mechanical malfunction occurs.
+5V
: Used for lighting external LEDs. 100 mA maximum for pins 2 and 14 together.
I/O
Pin No.
GND
14
O
15
BOD
O
16
EOD
O
17
O
18
EOT
O
19
O
20
O
21
REC
O
22
STOP
O
23
FWD
O
24
FF
O
25
REW
O
Signal name
Function
+5V
AUXILIARY POWER SUPPLY
GND
GND
RSV
RESERVED
RSV
RESERVED
RSV
RESERVED
IDINC
ID INCREMENT
IPAUSE
PAUSE
IREC
REC
ISTOP
STOP
IFWD
FWD
IFF
FF
IREW
REW
I/O
O
I
I
I
I
I
I
I