Sony SIR-1000W Instruction Manual page 109

High speed digital data recorder, channel expansion unit
Table of Contents

Advertisement

Command
TOC?
Command format
Returned format
TRG?
Command format
Returned format
TOC data read
TOC? <1><2><3>/[ ]
<1><2><3>: ID number
TOC:<1><2>...<25>
<1>: Start ID
0 = Not start ID, 1 = Start ID
<2>: REC mode
0 = 16 ch analog mode (standard)
1 = Full analog mode
2 = Full digital mode (when SBS-10A/S is used)
3 = Analog + digital mode
<3>: CH code
When <2> is 0, 1, or 3, which means analog CH mode.
1 = 2 ch, 2 = 4 ch, 3 = 8 ch, 4 = 16 ch, 5 = 32 ch, 6 = 64 ch, 7 = 128 ch
When <2> is 2, which means digital CH mode.
1 = 1 ch, 2 = 2 ch, 3 = 4 ch, 4 = 8 ch
<4>: Recording speed
0 = 1 × (normal speed), 1 = 1/2 ×, 2 = 1/4 ×, 3 = 1/8 ×, 4 = 1/16 ×,
A = 2 ×, B = 4 ×, C = 8 ×, F = EXT
<5>: Reservation
Always 0
<6>-<17> Recording start time
<6><7>: Year (last 2 digits)
<8><9><10><11>: Month and date
<12><13><14><15><16><17>: Hours, minutes and seconds
<18> : Existence of pre-trigger recording
0 = No pre-trigger recording
1 = Pre-trigger recording
<19> : Existence of recording error
0 = No write error
1 = Write error
<20><21><22><23><24><25>: Actual recording length
hhmmss
Related command: VOL?
Trigger mode setting status
TRG? /[ ]
TRG:<1>
<1>: 0 = Trigger invalid
1 = Pre-trigger single mode (low: start)
3 = Normal single mode (low: start)
Related command: TRG
Contents
2 = Pre-trigger multi mode (low: start, high: stop)
4 = Normal multi mode (low: start, high: stop)
12-19

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Scx-16w

Table of Contents