Sony SIR-1000W Instruction Manual page 110

High speed digital data recorder, channel expansion unit
Table of Contents

Advertisement

Command
TRM?
Command format
Returned format
TSG?
Command format
Returned format
UTL?
Command format
Returned format
VOL?
Command format
Returned format
12-20
Terminator selection status (returned strings)
TRM?/[ ]
TRM:<1>
<1>: 0 = CR + LF, 1 = CR, 2 = LF
Related command: TRM
Test signal selection status
TSG? /[ ]
TSG:<1>
<1>: Test signal selection
Analog channel
0=
OFF
1=
AC
2=
+DC
3=
–DC
4=
GND
5=
EXT
Related command: TSG
Utility mode setting read
UTL? /[ ]
UTL:<1><2><3><4><5><6>
<1>: 0 = AT FMT OFF
1 = AT FMT ON
<2>: 0 = ERA OFF
1 = ERA ON
<3>: 0 = DEW OFF
1 = DEW ON
Related command: UTL
Tape volume read
VOL? /[ ]
VOL:<1><2>...<32>
<1>: Format
0 = Standard
<2>: SIR type
0 = SIR-1000
1 = SIR-1000W
2 = SIR-1000i
<3><4><5><6>: Total IDs (max. 1000)
<7><8><9>: Total IDs inside MIC (max. 100)
<10><11><12><13><14>: TOC recording position (record number)
<15><16><17><18><19><20>: Last recorded SIR serial number
<21><22>: Last recorded year (last 2 digits)
<23><24><25><26>: Last recorded month and date
<27><28><29><30><31><32>: Last recorded hours, minutes and seconds
Related command: TOC?
Contents
Digital channel
OFF
010000000000000001000..
110000000000000000111..
010000000100000001000..
000000000000000000000..
010101010101010101010..
<4>: 0 = BOT EJCT OFF
1 = BOT EJCT ON
<5>: 0 = SKP ET03 OFF
1 = SKP ET03 ON
<6>: 0 = CMP MODE OFF
1 = CMP MODE ON

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Scx-16w

Table of Contents