H2: Auxiliary function outputs to PLC
8.7 Programming an auxiliary function
Program code
H5
H=5.379
H17=3.5
H[coolant]=13.8
H='HFF13'
H='B1110'
H5.3=21
432
Comment
; Output to PLC: H0=5
; Output to PLC: H0=5.379
; Output to PLC: H17=3.5
; Output to PLC: H12=13.8
; Output to PLC: H0=65299
; Output to PLC: H0=14
; Error
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions