Influencing The Stop Events Through Stop Delay Area - Siemens SINUMERIK 828D Function Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

K1: Mode group, channel, program operation, reset response
9.9 Program operation mode
9.9.13

Influencing the Stop events through Stop delay area

Stop Delay Area
The reaction to a stop event can be influenced by conditioned interruptible area in the current part program. Such
a program area is called stop delay area.
Within the stop delay areas there should be no stop and the feed should not be changed. Stops do not take effect
until the program section has been completed (Example: making of a thread).
A stop delay area is defined with the part program commands:
Start a Stop Delay Area
DELAYFSTON
End a Stop Delay Area
DELAYFSTOF
References:
Programming Manual, Job Planning;
Stop events
Overview of the NCK events that cause a stop:
NCK events
Reset and mode group RESET
PROG_END
Interrupt
DELDISTOGO_SYNC
PROGRESETREPEAT
PROGCANCELSUB
SINGLEBLOCKSTOP
SINGLEBLOCK_IPO
SINGLEBLOCK_DECODIER
STOPALL
STOPPROG
OVERSTORE_BUFFER_END_REACHED
PREP_STOP
PROG_STOP
STOPPROGATBLOCKEND
STOPPROGATSUPEND
WAITM
WAITE
INIT_SYNC
MMCCMD
588
Response
Stop criteria
immediate
IS: DB21, ... DBX7.7 and DB11 DBX20.7
Alarm 16954
NC prog.: M30
delayed
IS: "FC-9" and ASUP DB10 DBB1
immediate
IS: "Delete distance-to-go" DB21, ... DBX6.2 and axial
delayed
IS: "Clear number of subprogram passes" DB21, ...
DBX6.3
delayed
IS: "Program level abort" DB21, ... DBX6.4
delayed
In the stop delay area: NC stops at the end of the 1st
block outside the stop delay area.
Sinlge block is active before the stop delay area:
IS: "NC Stop at block limit" DB21, ... DBX7.2
delayed
IS: "Activate single-block type 1" DB11 DBX21.7
delayed
IS: "Activate single-block type 2" DB11 DBX21.6
immediate
IS: DB21, ... DBX7.4 and DB11 DBX20.6
delayed
IS: DB21, ... DBX7.3 and DB11 DBX20.5
Alarm 16954
NC prog.: Stop because of empty overstore buffer
Alarm 16954
NC prog.: STOPRE and all implicit Stopres
Alarm 16954
NC prog.: M0 and M1
delayed
IS: "NC Stop at block limit" DB21, ... DBX7.2
System fault
SR end should always deselect the stop delay section.
Alarm 16954
NC prog.: WAITM
Alarm 16954
NC prog.: WAITE
Alarm 16954
NC prog.: INIT with parameter "S"
Alarm 16954
NC prog.: MMC( STRING, CHAR )
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents