Siemens SINUMERIK 828D Function Manual page 929

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Typ
Signal
e
MCPBusType
I
HHU
I
BHGIn
I
BHGOut
I
BHGStatSend
I
BHGStatRec
I
BHGInLen
I
BHGOutLen
I
BHGTimeout
I
BHGCycl
I
BHGRecGDNo
I
BHGRecGBZNo
I
BHGRecObjNo
I
BHGSendGDNo
I
BHGSendGBZNo
I
BHGSendObjNo
I
BHGMPI
I
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Type
Value range
BYTE
INT
0, 5
POINTER
E0.0 to E124.0
or
M0.0 to M252.0
or
DBn DBX0.0 to DBXm.0
POINTER
A0.0 to A124.0
or
M0.0 to M252.0
or
DBn DBX0.0 to DBXm.0
POINTER
A0.0 to A124.0
or
M0.0 to M252.0
or
DBn DBX0.0 to DBXm.0
POINTER
A0.0 to A124.0
or
M0.0 to M252.0
or
DBn DBX0.0 to DBXm.0
BYTE
HHU default:
B#16#6 (6 Byte)
BYTE
HHU default:
B#16#14 (20 Byte)
S5time
Recommendation: 700 ms
S5time
Recommendation: 100 ms
INT
HHU default: 2
INT
HHU default: 2
INT
HHU default: 1
INT
HHU default: 2
Int
HHU default: 1
INT
HHU default: 1
BOOL
false
P3: Basic PLC Program for SINUMERIK 840D sl
Comment
Righthand half byte (bits 0...3) for MCP1
Lefthand half byte (bits 4...7) for MCP2
b#16#33: PROFIBUS
b#16#44: PROFIBUS on the MPI/DP port
b#16#55: Ethernet
B#16#66: PROFINET
Mixed mode possible, see Chapter "
Configuration machine control panel,
handheld unit, direct keys [Page 894] "
Handheld unit interface
0:
No HHU
5:
HHU on Ethernet
Start address
PLC receive data
from HHU
Start address
PLC transmit data
to HHU
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
Ethernet DIP switch
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
13.13 Block descriptions