3Relevant Sinumerik Documents; Nc Var Selector; 1Overview - Siemens SINUMERIK 828D Function Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

P3: Basic PLC Program for SINUMERIK 840D sl
13.12 Basic conditions and NC VAR selector
Reference manual STEP 7; Default and system functions
Manual STEP 7; Conversion of STEP 5 programs
STEP 7 overall index
Manual CPU 317-2DP
13.12.1.3 Relevant SINUMERIK documents
Reference:
Start-up manual SINUMERIK 840D sl
Device manual Operator Components SINUMERIK 840D sl / 840Di sl
Function Manual Basic Functions
Function Manual, Extended Functions:
Function manual, Special functions
Lists sl (Book1)
Lists sl (Book2)
13.12.2

NC VAR selector

13.12.2.1 Overview
General
The PC application "NC VAR selector" fetches the addresses of required NC variables and processes them for
access in the PLC program (FB 2/FB 3). This enables the programmer to select NC variables from the entire
range of NC variables, to store this selection of variables, to edit them by means of a code generator for the
STEP7 compiler and finally to store them as an ASCII file (*.AWL) in the machine CPU program. This process is
shown in the figure "NC VAR selector".
For storing the files created by NC-VAR-selector a catalog is to be implemented via the Windows Explorer with
any catalog name. The selected data of the NC-VAR selector (data.VAR and data.AWL files) must be stored in
this catalog. Thereafter, the AWL file is to be transferred and compiled via the menu option "Code" → "in STEP7
Project" The "Daten.AWL" (STL data) file must then be inserted into the STEP 7 machine project via "Insert",
"External Source" in the STEP 7 Manager. The source container must be selected in the manager for this
purpose. This action stores this file in the project structure. Once the file has been transferred, these AWL (STL)
files must be compiled with STEP 7.
Note
The latest NC VAR selector can be used for each NC software version (even earlier
versions). For older NC software versions the variables can also be selected from the latest
complete list. The data content in DB 120 (default DB for variables) does not depend on the
software status. That is, variables selected in an older software version need not be
reselected when the software is upgraded.