PI service: CONFIG
Function: Reconfiguration
The reconfiguration command activates machine data, which have been entered sequentially by the operator or
the PLC, almost in parallel.
The command can only be activated when the control is in RESET state or the program is interrupted (NC stop at
block limit). An FB 4 error checkback message is output if these conditions are not fulfilled (state = 3).
Parameterization
Signal
PIService
Unit
WVar1
PI service: DIGION
Function: Digitizing on
Selecting digitizing in the specified channel.
Parameterization
Signal
PIService
Unit
PI service: DIGIOF
Function: Digitizing off
Deactivating digitizing in the specified channel.
Parameterization
Signal
PIService
Unit
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Type
Value range
ANY
PI.CONFIG
INT
1
INT
1
Type
Value range
ANY
PI.DIGION
INT
1 to 10
Type
Value range
ANY
PI.DIGIOF
INT
1 to 10
P3: Basic PLC Program for SINUMERIK 840D sl
Meaning
Reconfiguration
Classification
Meaning
Digitizing on
Channel
Meaning
Digitizing off
Channel
13.13 Block descriptions