2
PROCEDURE BEFORE OPERATION
The following section shows the procedure until operation.
1.
Mounting modules on a base unit
Install the programmable Controller CPU and SECS/GEM communication software pre-installed model module on the base
module.
For the installation on the base module, refer to the following:
Module to be used
C intelligent function module
C Controller module
2.
Wiring of equipment
Connect the SECS/GEM communication software pre-installed model module, personal computer, and other network
equipment.
3.
Installation of a setting tool
Install a setting tool on a personal computer.
For the installation method, refer to the following:
Page 28 Setting tool
4.
Setting a firewall
When a Windows firewall is enabled and is set not to allow communication with the setting tool, communication may fail and a
timeout may occur.
To allow communication, set a firewall by the following procedure:
Page 18 Procedure for setting a firewall
When using other security software with a firewall function, refer to the manual of the software used and allow the
communication with the setting tool.
5.
Setting parameters
Configure the parameters of the programmable controller CPU and the SECS/GEM communication software pre-installed
model module.
For the setting method of the parameters, refer to the following:
Module to be used
C intelligent function module
C Controller module
6.
Network settings
Configure the network parameters.
For the configuration method, refer to the following:
Page 19 Network Setting
7.
SECS/GEM communication settings
Use the setting tool to configure the transaction information, communication settings, and device assignment settings
For the configuration procedure, refer to the following:
Page 20 SECS/GEM Communication Settings
*1 The SECS/GEM communication software (GEM version and GEM advanced version) has pre-registered variables defined by default.
For the storage register, "CPU-1" and "D0 device" are set temporarily.
Review these variable definitions and apply them to the device assignment settings.
8.
Setting update
Update the setting file stored on the SECS/GEM communication software pre-installed model module.
For the update procedure, refer to the following:
Page 129 Updating SECS/GEM Communication Software Pre-installed Model Module
2 PROCEDURE BEFORE OPERATION
16
Reference
MELSEC iQ-R Module Configuration Manual
MELSEC-Q C Controller Module User's Manual
Extended mode
Basic mode
C Controller Module User's Manual (Hardware Design, Function Explanation)
Reference
MELSEC iQ-R C Intelligent Function Module User's Manual (Startup)
Setting/Monitoring Tools for the C Controller Module Version 4 Operating Manual
Extended mode
C Controller Module User's Manual (Utility Operation, Programming)
Basic mode
*1
, etc.