Mitsubishi Electric MELSEC iQ-R Series User Manual page 161

C controller/c intelligent function module secs/gem communication software pre-installed model
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Display Setting
Series
MELSEC-Q series
MELSEC iQ-R series
Configure the details to display logs on a display.
Window
[Log]  [Log Output Setting]  [Display Setting] tab
Displayed items
Item
View the Log in
Programmable Display
Display Log Storage
Period
EOL processing
Maximum characters of
1 line
Maximum rows
The register of top for
operation (16bit)
The register of top for
drawing (5448Word)
Precautions
• The display log file is saved to the SD memory card when the MELSEC iQ-R series SECS/GEM communication software
pre-installed model module is being used.
• When a MELSEC-Q series SECS/GEM communication software pre-installed model module is being used, the display log
file is saved to the directory configured by the following setting: [CF Setting]  [Log Output Destination Folder].
• When a device of this host station is used, it must be configured in advance at a row lower than a device of another station
in "CA-SECS Device Assignment(I/O assignment)" of the "Device Assign Setting" screen.
SECS/GEM communication software
Non-GEM version
Description
Select this checkbox to view the log on the Programmable Display (GOT, etc.).
Configure the number of days to store log data to be displayed on the Programmable Display.
The log data is compiled into time-sliced files (in increments of hours) and saved for the specified
number of days.
Select the end-of-line processing when the number of characters per line is less than the maximum
number of characters.
Configure the maximum number of characters to be displayed on one line on the Programmable
Display.
Configure the maximum number of rows to be displayed on one screen on the Programmable Display.
Configure the device to be used for the operation register.
The 16 continuous points from the configured device can be used as the operation register.
Select "CPU-OWN" to specify an M device of the host station for the MELSEC-Q series SECS/GEM
communication software pre-installed model module.
For details on the operation register, refer to the following:
Page 168 View the log on display device (GOT)
Configure the device to be used for the display register.
The 5448 continuous words from the configured device can be used as the display register.
Select "CPU-OWN" to specify a D device of the host station for the MELSEC-Q series SECS/GEM
communication software pre-installed model module.
For details on the display register, refer to the following:
Page 168 View the log on display device (GOT)
GEM version
GEM advanced version
7 BASIC FUNCTIONS
159
7.17 Log Output
7

Advertisement

Table of Contents
loading

Table of Contents