7.14

Data Mapping Settings

Series
MELSEC-Q series
MELSEC iQ-R series
The mapping function can add sending request trigger relays and reception notification trigger relays to the selected
transactions and map offsets to the data control register as a command.
In this way, it is possible to configure as shown below for one transaction definition.
• Sending message: report data from control registers with different offsets by separating sending request trigger relays.
• Receiving message: assign control registers and reception notification trigger relays to register reception data by the values
of items.
Window
[Function]  [Data Mapping Setting]
Operations of the Command List
Operation
Right-click  shortcut menu [Modify]
Right-click  shortcut menu [Insert]
Right-click  shortcut menu [Duplicate]
Right-click  shortcut menu [Move Up]
Right-click  shortcut menu [Move Down]
Right-click  shortcut menu [Delete]
SECS/GEM communication software
Non-GEM version
Description
Display the "Command Setting" screen to modify the content of the selected command setting.
Add a new command setting.
Copy the selected command setting, and then add the copied command setting to the row below.
Move the selected command setting.
Delete the selected command setting.
GEM version
7.14 Data Mapping Settings