Conversion data list

Register data of before and after conversion to a conversion table.
Up to 32767 units of conversion data can be registered.
Window
Click the [Conversion Data] button in the "Conversion Table" screen.
Operations of the Conversion Data List
Operation
Right-click  shortcut menu [Modify]
Right-click  shortcut menu [Insert]
Right-click  shortcut menu [Duplicate]
Right-click  shortcut menu [Move Up]
Right-click  shortcut menu [Move Down]
Right-click  shortcut menu [Delete]

Conversion data setting

Window
Select conversion data in the "Conversion Data List" screen, right-click  shortcut menu [Modify]
Displayed items
Item
SECS Data
PLC Data
Comment
7 BASIC FUNCTIONS
146
7.15 Conversion Table Setting
Description
Display the "Conversion Data" screen to modify the content of the selected conversion data.
Add a new conversion data.
Copy the selected conversion data, and then copy the copied conversion data to the row below.
Move the selected conversion data.
Delete the selected conversion data.
Description
Configure the data to be handled in SECS messages.
Data is regarded as before replacement during reception and after replacement during sending.
Configure the data to be handled in control registers.
Data is regarded as after replacement during reception and before replacement during sending.
A comment can be entered.