Advertisement

4 Repair
4.19.3 Replacement of line filter
Continued
Removal
Use the following procedure to remove the line filter.
1
2
3
4
5
6
Continues on next page
198
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety in-
formation in section
DANGER - Make
sure that the main power has been
switched off! on page
33.
Remove the cover of the cabinet.
Disconnect connector X1 from the sys-
tem power supply.
Disconnect the ground connection.
Disconnect and remove the safety board
unit to be able to access the secondary
side of the line filter.
Disconnect the cables from L1', L2' on
the secondary side of the line filter.
© Copyright 2009-2017 ABB. All rights reserved.
Note/illustration
See
Opening the IRC5 Compact controller on
page
89.
xx1400002853
A Connector X1
B Ground connection
See
Replacement of Remote Service box on
page
181.
A
xx1400002854
A Line filter connections